- ATTACH
- VAX_780
ATT DW780 HUB DWn 3 4 ! attaches the DW780
ATT TU81 DW0 MUA0 774500 260 5 ! attaches the TU81
- VAX_750
ATT DW750 HUB DWn ! attaches the DW750
ATT TU81 DW0 MUA0 774500 260 5 ! attaches the TU81
- VAX_730
ATT DW730 HUB DWn ! attaches the DW730
ATT TU81 DW0 MUA0 774500 260 5 ! attaches the TU81
- VAX_8200
ATT DWBUA HUB DWn n 4 ! attaches the DWBUA,
or ! where n = BI node ID
ATT DWBLA HUB DW0 n ! attaches the DWBLA
! where n = BI node ID
ATT TU81 DW0 MUA0 774500 260 5 ! attaches the TU81
- VAX_8800
ATT NBIA HUB NBIAn ! attaches the NBIA, VAX 8800
LOGICAL ADAPTER # ? N ! n = 0 or 1
ATT NBIB NBIAn ! attach for VAX 8800 con't.
Device Name ? NBIBn ! where n 0 to 3
BI # ? n ! 0 or 1
BI Node Number (HEX) ? n ! n 0 to F
ATT DWBUA NBIBn DW0 m ! attaches DWBUA
or ! m = BI node number 0 to F Hex
ATT DWBLA NBIBn DW0 m ! attaches DWBLA
! m = BI node number 0 to F Hex
ATT TU81 DW0 MUA0 774500 260 5 ! attaches the TU81
- DEVICES
EVMBB supports up to 4 TU81 Controllers with TU81 streaming tape Drives.
- TU81
Device: TU81
Link: MUAn
Generic name: MUAn
Additional information:
CSR : [octal 760000-777774] <774500>
VECTOR: [octal 4-774] <260>
BR: [decimal 4-7] <5>
- SECTION
Defines the diagnostic program sections (/SECTION qualifier on RUN or
START) which program supports.
- DEFAULT
Evoked by typing: ST <return>
RUN EVMBB <return>
Runs default tests (Tests 1-9).
- MANUAL
Evoked by typing: ST/SEC:MANUAL <return>
RUN EVMBB/SEC:MANUAL <return>
Runs manual section test (Test 10).
- FAULT
Evoked by typing: ST/SEC:FAULT <return>
RUN EVMBB/SEC:FAULT <return>
Runs the fault section Tests (Tests 11,12,13).
This section runs drive resident tests #2 and #3,
then allows the operator to select any other
TU81 Drive resident test (1-99).
- HELP
EVMBB is a Level 3 Functional diagnostic for the TU81 TAPE SUBSYSTEM.
of the 13 tests, Test 1 through Test 9 can be run by DEFAULT.
Test 10 is in the MANUAL section and runs drive resident test #1.
Tests 11,12,13 are in the FAULT section and runs drive resident test
#2 and #3, then allows the operator to select any other
TU81 Drive resident test (1-99).
- SELECT
SEL MUAn ! selects the controller/drive to test