- HELP
EVDWA is a level 3 diagnostic. The diagnostic runs stand-alone
under the Diagnostic Supervisor. It is composed of 19 tests.
Many of the tests involve subtests.
Other information is available via the HELP facility under
the following categories:
ATTACH START SECTIONS CONFIG
DEVICE EVENT_FLAGS QUICK SUMMARY
RUN_TIME
- ATTACH
The following example show those commands necessary to
ATTACH and SELECT both the UNIBUS adabpter and the UNA11.
(This example for attachment to an 8600 processor)
DS> ATT SBIA HUB SI0
DS> ATT DW780 SI0 DW0 3 4
DS> ATT UNA11 DW0 XEA0 774510 120 5
DS> SEL ALL
DS> START
(This example for attachment to an 11/780 processor)
DS> ATT DW780 HUB DW0 3 4
DS> ATT UNA11 DW0 XEA0 774510 120 5
DS> SEL ALL
DS> START
(This example attaches to the VAX 11/750)
DS> ATT DW750 HUB DW0
DS> ATT UNA11 DW0 XEA0 774510 120 5
DS> SEL ALL
DS> START
(This example attaches the VAX 11/730)
DS> ATT DW730 HUB DW0
DS> ATT UNA11 DW0 XEA0 774510 120 5
DS> SEL ALL
DS> START
(This example for attachment to an VAX 8200 processor)
DS> ATT DWBUA HUB DW0 n 4 where n = node ID of BUA
DS> ATT UNA11 DW0 XEA0 774510 120 5
DS> SEL ALL
DS> START
(This example for attachment to an VAX 8800 processor)
DS>ATTACH NBIA HUB NBIAn ! where n 0 or 1
DS>LOGICAL ADAPTER # ? N ! 0 or 1
DS>ATTACH NBIB NBIAn
DS>Device Name ? NBIBn ! where n 0 to 3
DS>BI # ? n ! 0 or 1
DS>BI Node Number (HEX) ? n ! n 0 to F
DS>ATT DWBUA NBIBn DW0 x 4 ! where x = BI node # 0-F
DS> SEL ALL
DS> START
- START
Executes image'EVDWA.EXE' that was previously loaded
by the LOAD or by a previous RUN command. Executes the image
by passing control first to the program's initialization
code and then sequentially to each test within the program.
Format:
START [qualifiers]
- Qualifiers
/SECTION:section-name
This feature is not implemented in this repair-level diagnostic.
/TEST:first[:last]
If the 'first' and 'last' arguments are specified, the supervisor
sequentially passes control to tests 'first' through 'last'
inclusively.
If only the first argument is specified with the TEST switch, the
last argument is assumed by default to be the highest numbered
test within the program.
/PASSES:count
After program execution has been completed, as defined by use of
other qualifiers, count is decremented and execution continues;
the program will loop through the specified cycle 'count' times.
If the /PASSES qualifier is not used,'count' defaults to 1.
- SECTIONS
This feature has not been implemented in this repair-level
diagnostic.
- DEVICE
UNA11
Description: UNIBUS to NI ADAPTER
link: DW0
recommended generic: XEA0
Additional information:
CSR 774510 [OCTAL 760000-777776]
VECTOR 120 [OCTAL 2-776]
BR 5 [DECIMAL 4-7]
- EVENT_FLAGS
The TRACE flag may be used to track progression of the
diagnostic through the tests and subtests.
diagnostic.
- QUICK
The QUICK feature is not implemented in this diagnostic.
The diagnostic execution time for EVDWA is about 110 seconds.
- SUMMARY
This feature is not implemented in this diagnostic.
- CONFIG
This diagnostic requires that the link cable be terminated.
The cable from the Link board must either be connected to
the network transceiver or must have a test loopback connector
installed.
- RUN_TIME
This diagnostic takes approximately 110 seconds to run with
a single unit under test.