- HELP
EVDUQ TESTS DUP11 SYNCRONOUS INTERFACE TRANSMIT/RECEIVE FUNCTIONS
- DEVICE
EVDUQ is a VAX11 Level 3 diagnostic for the DUP11 synchronous
communications interface. To use EVDUQ perform a Stand-alone Boot,
LOAD EVDUQ and ATTACH the DUP11.
- ATTACH
EXAMPLE. Answer hardware questions in octal. UNIBUS CSR and VECTOR
addresses must agree with the switch packs on the DUP11 board.
using the diagnostic stand alone supervisor
DIAGNOSTIC SUPERVISOR. ZZ-ENSAA-6.10-YYY 8-FEB-1982 09:40:14.80
DS> LOAD EVDUQ ; LOAD THE DIAGNOSTIC PROGRAM
;
DS> ATTACH SBIA HUB SI0 ; USE FOR VAX/8600 ONLY
;
use one of the following
DS> ATTACH DW780 SI0 DW0 3 4 ; VAX/8600
DS> ATTACH DW780 HUB DW0 3 4 ; ATTACH THE UBA (VAX/780)
DS> ATTACH DW750 HUB DW0 ; VAX/750
DS> ATTACH DW730 HUB DW0 ; VAX/730
DS> ATTACH DWBUA HUB DW0 node 4 ; VAX 8200/8300
; For the VAX 8800
DS> ATTACH NBIA HUB NBIA0 0 ; ATTACH THE NBIA
DS> ATTACH NBIB NBIA0 NBIB0 0 Node ; ATTACH THE NBIB
DS> ATTACH DWBUA NBIB0 DW0 Node 4 ; ATTACH THE DWBUA
DS> ATT DUP11 ; ATTACH THE DUP11
DEVICE LINK? DW0 ; LINK TO THE UBA
DEVICE NAME? XWA0 ; THIS IS THE DUP11 DEVICE NAME
CSR? 760050 ; USE INSTALLATION SPECIFIC CSR ADDRESS
VECTOR? 300 ; USE INSTALLATION SPECIFIC VECTOR
BR? 5 ; BR INTERRUPT LEVEL IS 5
DS> SELECT XWA0 ; SELECT DEVICE.
DS> SET TRACE ; PRINT TEST IDs (OPTIONAL)
DS> START ; START TEST
- FLAGS
Use flags if the DUP11 test configuration is not the same as the
EVDUQ default configuration.
DEFAULTS
H325 test connector is ON If OFF type DS> SET EVENT FLAG 1
XMIT optional jumper is ON If OFF type DS> SET EVENT FLAG 2
RCVR optional jumper is ON If OFF type DS> SET EVENT FLAG 3