- HELP
EVDRB is a Level 2, Functional diagnostic for the DR11W option.
- DEVICE
EVDRB supports the DR11W option.
- DR11W
Device: DR11W
Link: DWn
recommended generic: XAa
Additional information:
CSR address: 760240*
Vector address: 300*
BR level: 5
* = (These addresses are UNIBUA configuration dependent)
- ATTACH
DS> ATT DW780 HUB DW0 3 4 ; attaches UBA TO 11/780
OR
DS> ATT DW750 CMI DW0 ; attaches UBA to 11/750
OR
DS> ATT DWBUA HUB DW0 node 5 ; attaches DWBUA to 8200
; where node is cpu node
DS> ATT DR11W DWn XAa 760240 300 5
; attaches DR11W
DS> SELECT XAa ; selects device to be run.
- DATA-PATTERNS
Data patterns used are: All Zeroes, All Ones, Floating Zeroes,
Floating Ones and CCITT 511 bit pattern.
Transfer sizes are: 16, 64, 512 and 1000 bytes.
- SECTIONS
There are two sections in EVDRB: MAINTENANCE and CABLE
- EVENT-FLAGS
Event flags are not used by this diagnostic.
- QUICK
The QUICK feature is not implemented in this diagnostic. The diagnostic
execution time is less then one minute for an error free pass.
- SUMMARY
The SUMMARY report includes: Total Hard Errors, Total Data Compare Errors
and Total Words transfered.
- ERRORS
For specific error messages, see Program Documentation.
- CABLE
This Test requires the use of a BC05L turnaround cable.
Switch Pack 105 should be set as follows:
SW1=OFF
SW2=ON
SW3=OFF
SW4=OFF
SW5=ON
- MAINTENANCE
This is the DEFAULT SECTION and requires no operator intervention.