- HELP
EVDEB is the first of six level 3 diagnostics designed to perform static and
functional testing of the DV11 Communications Multiplexer. EVDEB does R/W
tests on both primary and secondary registers to verify that no interaction
between registers exists. It also exercises all microcode instructions and
verifies internal registers used by the microprocessor. Interrupts and NPRs
are also tested. NOTE: All line/modem control cards may be removed for ease
of diagnosis.
- ATTACH
DS> ATT DW780 SBI DW0 3 4 ; attaches UBA TO 11/780
OR
DS> ATT DW750 CMI DW0 ; attaches UBA to 11/750
The following is an example of attaching a DV11:
DS> LOAD EVDEB ; LOAD DIAGNOSTIC
DS> ATT DV11 DW0 DVA0 0 775000 470 5; Attach DV11 to UBA w/logname DVA(n),
; unit #(0-7),address,vector,priority.
; ATTACH M7839 LINE CARD(S):
DS> ATT M7839 ;(REPEAT FOR EACH SYNCHRONOUS LINE CARD)
DEVICE LINK? DVA0 ; DV11 Logical name of DVA(n)
DEVICE NAME? LC0 ; Logical name of line card (LC0-LC3)
LINE_CARD? 0 ; Physical line # (0-3)
SYNCA? 226 ; Sync Character "A"
SYNCB? 62 ; Sync Character "B"
CHAR_SIZE? 8 ; Number of bits/character (5-8)
PARITY? NO ; Parity (YES,NO)
EVEN? NO ; Even (YES,NO), NO=odd parity
2SYNCS? YES ; Two sync characters (YES,NO),NO=one
LINE0? YES ; Active lines (YES,NO) : actual line
LINE1? YES ; selection not supported by EVDEB.
LINE2? YES ;
LINE3? YES ;
; ATTACH M7833 LINE CARD:
DS> ATT M7833 ;(REPEAT FOR EACH ASYNCHRONOUS LINE CARD)
DEVICE LINK? DVA0 ; DV11 Logical name of DVA(n)
DEVICE NAME? LC1 ; Logical name of line card (LC0-LC3)
LINE_CARD? 1 ; Physical line # (0-3)
LINE0? YES ; Active lines (YES,NO) : actual line
LINE1? YES ; selection not supported by EVDEB
LINE2? YES ;
LINE3? YES ;
;
DS> SELECT ALL ; or SEL <device>
DS> START ; START DIAGNOSTIC.
- SECTIONS
No special SECTIONS supportred in EVDEB.
- DEVICE
Devices supported by EVDEB are:
DV11 Communications Multiplexer
M7839 Synchronous Line Card
M7833 Asynchronous Line Card
- DV11
Device: Communications Multiplexer
link: DW0
recommended generic: DVA0 (for 1st DV11)
Additional information:
CSR address: 775000 (for 1st DV11)
Vector Address: 300 (for 1st DV11)
Priority: 5
- M7839
Device: Synchronous Line Card
link: DVA0 (DV11 logical name)
recommended generic: LC0 to LC3
Additional information: Four lines/card, four cards max/DV11
- M7833
Device: Asynchronous Line Card
link: DVA0 (DV11 logical name)
recommended generic: LC0 to LC3
Additional information: Four lines/card, four cards max/DV11
- EVENT
This program does not use event flags.
- QUICK
This program does not implement the QUICK feature.
- SUMMARY
The Summary command is not supported in this program.