- HELP
EVCKA is the first of six Repair Level Diagnostics for the CIBCI
(BI to CI adapter). It is comprised of twenty eight - tests.
To run EVCKA, boot in the VAX 8200/8300, 8800
compatible Diagnostic Supervisor. (For 8200/8300 EBSAA and
for 8800 EZSAA)
Each time information is desired on keywords
it is necessary to type HELP EVCKA 'keyword'.
- ATTACH
BI Node Number: [hex 0-F] determined by address plug on BAC
BR Level: [4-7] fixed at 4
CI Node Number: [dec 0-255] switch select on Link Bd
Example: For VAX 8200/8300
ATTACH CIBCI HUB PAA0 2 4 14 ; BI node 2, BR level 4, CI node 14
SELECT PAA0 ; selects device to be run
Example: For VAX 8800
ATTACH NBIA HUB NBIA0 0 ; logical unit 0
ATTACH NBIB NBIA0 NBIB0 1 0 ; BI #1, BI node 0
ATTACH CIBCI NBIB0 PAA0 2 4 0 ; BI node 2, BR level 4, CI node 0
SELECT PAA0 ; selects device to be run
- SECTIONS
Sections names have been generated for tests that test
common hardware and/or similar functions. The user can run
any individual section by typing START/SECTION:SECTION NAME
The following sections are available in EVCKA:
BAC, BAD, CIPA
where
BAC is the BICA Control module,
BAD is the BICA Data module, and
CIPA is the CIPA box.
- EVENT_FLAGS
- 4
If event flag 4 is set then the revision level of the BIIC chip will
be output in Test 3.
- 5
If event flag 5 is set then the message pertaining to
the use of event flag 4 will not get printed in the header.
in the header.
- QUICK
The QUICK feature is not implemented in this diagnostic.
The diagnostic execution time for EVCKA is 12 seconds on VAX 8200/8300,
and 15 seconds on VAX 8800.
- SUMMARY
The Summary report gives an error count by test number. No report is
generated if there were no errors.
Type "SUMMARY"