- ATTACH
First attach the Unibus
DS> ATTACH DW780 SBI DWn 3 4 (11/780)
or
DS> ATTACH DW750 CMI DWn (11/750)
Then attach the LPA11-K
DS> ATTACH LPA11K DWn LAAn 770460 340 5
Where n is any arbitrary number
- HELP
This diagnostic is used to test and or calibrate an LPA11-K
system. Until a driver EVQLA is released the program will
execute under VMS only. The authorization file should be setup
as follows:
USERNAME: ? OWNER: ?
ACCOUNT: ? UIC: [?]
DIRECTORY: ? DEVICE: ?
LOGIN COMMAND FILE: ? LOGIN FLAGS: ?
CLI: DCL PRCLM: 10 PRIO: 4
ASTLM: 10 BIOLM: 8 BYTLM: 4096
DIOLM: 8 FILLM: 20 TQELM: 10
WSDEFAULT: 150 WSQUOTA: 200 PGFLQUOTA: 40
PRIVLIDGES:
GRPNAM DIAGNOSE LOGIO GROUP PRMCEB PRMMBX TMPMBX
PHYIO PSWAPM ALTPRI
- SECTIONS
DEFAULT - This section executes tests 1 thru 32.
ADCAL - This section is used to calibrate the A/D Converter(s)
DACAL - This section is used to calibrate the D/A Converter(s)
- DEVICE
- LPA11-K
Device: LPA11-K System
Link: DWn
Recommended generic: LAAn
Additional Information:
CSR? 770460
VECTOR? 340
BR? 5
The maximum configuration of the LPA11-K system is:
One KW11-K
Two AD11-K
One AA11-K
Five DR11-K
- EVENT
Event flags 1 thru 9 are used and grouped according to the
device within the LPA11-k system to which they apply.
- DR11-K
Event flags 1 thru 5 indicate loopback cable is present for
DR11K's 1 thru 5 respectively.
- AD11-K
Page 2
Event flags 6 and 7 indicate that wraparound module G5036 is
present for AD11K's 1 and 2 respectively.
- AA11-K
Event Flag 8 - Setup for two's compliment
Event Flag 9 - Channels 2 and 3 to be used as output
- QUICK
Not Used
- SUMMARY
Not Implemented