- ATTACH
The CPU must be attached.
Example:
ATTACH KA785 SBI KA0 Y/N Y/N 1FFF 0/1
- HELP
This program is a level 3 diagnostic that tests most portions
of the VAX 11/785 CPU cluster hardware that are not specified
by the VAX architecture. The areas tested by this program are
reserved processor registers, power fail, processor halts, WCS,
Machine Checks, and the RX01. This program MUST run in a
standalone environment under control of the Diagnostic
Supervisor. THIS PROGRAM IS NOT DESIGNED TO RUN WITH MEMORY
MANAGEMENT ON.
- SECTION
- DEFAULT
This section executes the Internal Processor Register tests,
the HALT tests (executed on the first pass ONLY), the Writable
Control Store (WCS) test and the Machine Check Exceptions and
Interrupts test.
- POWER_FAIL
This section executes the Power Fail test. THE CPU MUST HAVE
BATTERY BACKUP FOR THIS MANUAL INTERVENTION TEST TO EXECUTE
PROPERLY.
- RX01
This section executes the RXCS and Track/Sector exerciser test.
The test prompts you to install a scratch floppy in the Console
RX01.
- ALL
This section executes ALL tests in all sections.
- EVENT
Event flags are not used in this diagnostic.
- QUICK
The QUICK flag is not implemented in this diagnostic.
- SUMMARY
The summary report gives an error count by test number. No
report is generated if there were no errors.