- HELP
ESDID, a REPAIR level (Level 3) diagnostic, contains a series
of tests which will establish the functionality of the KMS11-BL/BM option.
. The program provides error messages which identify data and I/O
errors. The program runs with the Diagnostic Supervisor from the
system console in a STAND-ALONE environment.
- DEVICE
Devices supported by this program (ESDID) are:
KMC11-B (M8206) MICROPROCESSOR
M8201 LINE UNIT
M8202 LINE UNIT
- KMC11-B
Device: KMC11
Link: DW0
Recommended Generic KMn
Additional Information:
Unibus CSR: [octal 760000-777770] (default 760150)
Unibus Vector: [octal 2-776] (default 350)
Unibus BR Level:[decimal 4-7] (default 5)
- EVENT
EVENT 4 = M8201 (DEFAULT)
EVENT 5 = M8202
EVENT 8 = KMC11-B (DEFAULT)
EVENT 10= EXTERNAL CABLE LOOPBACK (DEFAULT IS EVENT 10 NOT SET)
- QUICK
Not Applicable.
- SUMMARY
None.
- ATTACH
Example command strings to ATTACH and SELECT the KMC11-B
ATTACH DW780 SBI DW0 3 4
ATTACH KMC11 DW0 KMA 760150 350 5
SELECT KMA
- REQUIREMENTS
HARDWARE:
KMC11-B (M8206)
M8201 OR M8202
SOFTWARE:
VAX Diagnostic Supervisor (minimum, Version 6)
- SECTIONS
The ESDID program contains the following sections:
SECTION NAME MNEMONIC TYPE
------------ -------- ----
DEFAULT DEFAULT DEFAULT
- DEFAULT
DEFAULT TEST SECTION
The DEFAULT test section will run all of the tests in
ascending order. There are no other test sections.